Skip to content

GCRI · Foundry

컴퓨팅과 엣지

Risk analysis needs compute in very different places: a large cloud allocation for a national ensemble, a ministry’s own servers for records that may not leave, a field laptop that keeps a model running when the network fails. This page sets out how compute risk develops, from capacity shortfall and concentration in a few providers to jurisdiction, energy and degraded connectivity, and how cloud, local nodes and edge devices are designed to be scheduled as one capacity.

01등록

컴퓨트와 엣지에 관한 기록.

02질문

Compute and edge: how the risk develops.

클라우드, 로컬 노드, 엣지의 기술 역량. 아래 자료는 리스크가 어떻게 전개되는지, 무엇을 측정하는지, 데이터는 어디서 오는지, 어떻게 모델링되는지, 누가 결정하는지를 설명합니다.

메커니즘

Capacity fails when needed

Demand for compute peaks during events, exactly when shared capacity is contested, networks are degraded and power is unstable. Queues lengthen, ensembles shrink and forecasts arrive after the decision window has closed.

메커니즘

집중도

Many institutions rely on a few cloud providers, regions and chip suppliers. An outage, sanction, price change or supply shortage reaches all of them at once, which makes compute concentration a systemic dependency in its own right.

메커니즘

관할권과 데이터 위치

Where data may be processed is set by law and contract. Moving analysis to the data keeps records in place, but constrains which methods can run and can still leave results open to inference about the inputs.

메커니즘

연결 해제와 조정

Edge nodes keep working offline and reconcile later. Conflicting edits, clock skew and stale models accumulate during an outage, and reconciliation after a long disconnection may need human judgement rather than an automatic merge.

03방법과 근거

How compute and edge is modelled, measured and tested.

모형, 그 가정, 데이터, 불확실성을 과학자나 엔지니어가 확인할 형태로 제시합니다. 구조는 발행된 방법을 따릅니다. 제시된 값은 예시이며 결과가 아닙니다.

모형, 방정식 및 가정

The model structure used for compute and edge, the assumptions it makes and how each is tested.

요소 i의 리스크Ri = f(Hi, Ei, Vi, Ci)재해, 노출, 취약성, 대처 역량
연간 기대 손실EAL = ∑k pk · Lkover events k with annual probability pk
결합 시스템xt+1 = A xt + B ut + εtA carries the couplings, u the shock, ε the error
가정만드는 이유시험 방법
한 사건 안에서 재해와 노출은 서로 독립적임손실 적분을 다루기 쉽게 유지함결합 기록에 적합한 코퓰러와 비교
결합은 운전점 근처에서 선형이다충격이 A를 통해 전파되게 함선형 범위를 넘어 섭동을 주고 비교하십시오
취약성 곡선은 장소 간에 옮겨 쓸 수 있다지역 곡선은 거의 없다관측된 손실이 있는 곳에서는 이에 대해 검증
투입 자료
출처 정보가 있는 버전 관리 데이터세트
산출물
분포이며 결코 단일 숫자가 아님
코드
모델 카드 및 시험과 함께 공개
재현
같은 데이터, 코드, 환경과 시드
표준 리스크 및 상태공간 정식화로, 나열된 가정은 해당 방법에 일반적인 것이며 검토를 위해 명시한 것으로 결과가 아닙니다.
FAIR 지침 원칙 · GO FAIR와 FORCE11W3C PROV · 월드 와이드 웹 컨소시엄불확실성의 일관된 처리에 관한 지침 · IPCCCEOS 분석 준비 데이터(Analysis Ready Data) · 지구관측위성위원회
04다섯 도메인에서

Compute is designed to serve each domain’s heaviest models.

05지표

측정되는 것과 그 정확도.

각 지표에는 단위, 주기, 그 뒤의 출처 종류, 값에 붙을 근거 표시가 있습니다. 값은 표시하지 않습니다. 값은 프로그램이 자체 권한으로 제공합니다.

지표단위주기출처 유형라벨
대기열 대기 시간minutes, median and tail일별Scheduler accounting관측
서비스 가용성proportion of scheduled time월별가용성 모니터링관측
Workloads placed outside permitted jurisdiction건수per placementPlacement policy logs관측
Edge reconciliation conflicts재동기화당 횟수사건별동기화 로그관측
워크로드당 에너지 사용량kilowatt-hours실행당Power telemetry or provider estimates추정
Carbon intensity of electricity usedgrams CO2 equivalent per kilowatt-hour시간별Grid operator and provider data추정
Capacity offered against capacity allocatedcore-hours or GPU-hours월별Offer and allocation register신고됨
Recovery time in failover exercises분훈련당훈련 기록관측
06출처

근거의 출처.

이름이 명시된 공개 데이터셋과 기관 기록으로, 각각 라이선스 등급이 있습니다. 협약에 따른 출처는 그 조건에 따라서만 사용하며 결코 재게시하지 않습니다.

출처제공하는 것라이선스 등급
TOP500 및 Green500 목록대규모 시스템Free, terms of the project
Ember 전력 데이터Generation mix and carbon intensity of electricity by countryCC BY 4.0
Copernicus Data Space Ecosystem데이터 가까이에서 처리하는 지구관측 아카이브무료 공개, 출처 표시
NASA Earthdata CloudEarth science archives in cloud object storage for in-region analysisFree and open, NASA data policy
퍼블릭 클라우드 리전 및 상태 기록Region locations, availability history and incident reportsProvider terms
Kubernetes release and deprecation recordsVersion support windows and API removals that affect workload portabilityCC BY 4.0
07결정

누가 결정하며 근거는 무엇에 쓰이는지.

Foundry는 근거를 준비합니다. 아래 결정은 명시된 기관이 각자의 규칙에 따라 내리며, 플랫폼이 내리는 것이 아닙니다.

결정 주체질문이 페이지가 제공하는 근거
데이터 소유자와 개인정보 보호 당국데이터를 어디에서 처리할 수 있는지, 그리고 결과를 외부로 반출할 수 있는지 여부Placement logs, the jurisdiction of each tier, federated execution records
프로젝트 소유자How to prioritise workloads within an allocation during an event대기열 상태, 남은 배정량, 마감일
Infrastructure contributors and operatorsWhat capacity to offer and on what terms제공 등록부, 이용률, 에너지 및 지원 부하
디지털 인프라 담당 부처How far national risk analysis depends on foreign or concentrated providersProvider and region dependency map; exit and failover plans

이 주제가 생산하는 산출물

  • Placement policies by data class, jurisdiction, urgency and cost
  • Workload packages portable across cloud, private and edge tiers
  • Failover and degraded-operation runbooks with exercise records
  • Register of capacity offered, allocated and used, kept apart
08핵심 질문

What computing engineers and data owners ask.

  • Where is the data legally and contractually allowed to be processed?
  • Which workloads need burst capacity, and which need steady, local availability?
  • How does work continue when connectivity is degraded or lost?
  • How is offered capacity distinguished from capacity actually allocated and used?
09메커니즘

One control plane across three tiers.

NXS-COR (compute, nodes and runtimes) is designed as the compute control plane across cloud, private infrastructure and edge. Workloads are packaged with their dependencies so they can run on any tier that the project’s policy allows, and the scheduler places them according to data location, sensitivity, cost and urgency. Where data cannot move, the analysis is designed to run where the data is held and only permitted results leave.

Edge capacity matters most when it is hardest to provide: during the events risk work is about. Field kits, observatory nodes managed through NXS-OPS (instruments, sensors and calibration) and offline operation of NXS-NST (civilian common operating picture) are designed so that coordination continues through outages, synchronising when connectivity returns. Energy use, cooling and hardware supply are part of the engineering, and the platform’s computing questions connect to the energy and data-centre analysis at Data and Compute.

10방법과 한계

What is engineered, and what remains hard.

Federation

Compute to data

Federated execution keeps sensitive data in place and moves code and permitted results.

회복력

Degraded operation

Edge nodes continue locally and reconcile later, with conflicts flagged rather than silently overwritten.

Accounting

Offer is not allocation

Contributed infrastructure is recorded as an offer until it is separately allocated.

Limits: federated analysis constrains which methods can run, edge devices have little capacity, and reconciliation after long disconnection can need human judgement. No hardware specifications are summed into performance claims.

12Where this page’s references

Where this page’s references lead.

이 페이지를 읽을 때 기준이 되는 기구와 문서. 상태와 판은 바뀌며, 각 링크는 발행 기구로 연결됩니다.

13질문

질문과 답변.

Why move analysis to the data instead of the reverse?
Because some data may not legally or contractually leave its location, and some is too large to move. The code goes to the data, runs under the owner’s policy, and only permitted results come back.
What happens to edge work during an outage?
The node continues locally with the model and data it holds. When connectivity returns it synchronises and flags conflicts for a person to resolve rather than overwriting either side.
Can my institution contribute servers?
Offers can be described to the Consortium Secretariat. An offer is recorded as an offer, not as allocated or used capacity, until a separate allocation is agreed.
Is energy use reported?
The design records energy and carbon per workload where telemetry or provider estimates exist, with a label stating which. Estimates are never presented as measurements.
회원 자격에 컴퓨팅 자원이 포함됩니까?
아니요. 회원 자격이나 후원 모두 컴퓨팅 할당을 보장하지 않습니다.
Is any compute allocation open?
Not yet. Allocations open when their terms and review capacity exist.
보고서기여하기

이 페이지에서 증거를 기여하십시오.

Reports는 컨소시엄의 분기별 간행물입니다. 이 주제에 관해 귀하가 아는 것은 다음 호에서 근거, 사례 또는 정정이 될 수 있으며, 귀하의 이름으로 표시되고, 귀하 자신의 저작인 경우 CC BY 4.0으로 발행됩니다.

GCRI지역 임무에서 가장 많이 사용하는 FoundryFoundry 구축과 준비도
지역 임무에서 가장 많이 사용하는 Foundry

방법, 데이터세트 또는 질문을 가져오십시오.

정보와 문의는 오늘부터 열려 있습니다. 문의에는 참조 번호가 부여되고 다음 단계가 안내됩니다. 신청, 결제, 컴퓨팅 할당, 등록은 해당 팀, 약관, 심사 역량이 갖추어졌을 때만 열립니다.

The Global Centre for Risk and Innovation (GCRI Canada) is a Canadian not-for-profit organisation, not a registered charity, with its registered office in Ontario.